0.66/1.14kV and below coal mine used mobile flame-retardant flexible cable
Page view
产品名称

0.66/1.14kV and below coal mine used mobile flame-retardant flexible cable

没有此类产品
Contact Us
PRODUCT DESCRIPTION

Use
This product is mine used rubber-sheathed flexible cable and is suitable for power connection of mobile coal cutter units with a rated voltage of 0.66/1.14kV and below and other devices.

Working conditions
The long-term allowable working temperature of cable conductor is 65 ℃, the minimum bending radius of the cable is 6 times of the cable diameter. The yellow sheathed cable shall not be exposed to sunlight for a long time.

Type、Name、Use

Type Name Use
MY-0.38/0.66 Coal mine used mobile rubber-sheathed flexible cable Power connection of various underground mobile coal mining devices with a rated voltage of 0.38/0.66kV
MYE-0.38/0.66 Coal mine used mobile elastomer flexible cable Power connection of various underground mobile coal mining devices with a rated voltage of 0.38/0.66kV
MYP-0.38/0.66 Coal mine used mobile shield rubber sheathed flexible cable Power connection of various underground mobile coal mining devices with a rated voltage of 0.38/0.66kV
MYPE-0.38/0.66 Coal mine used mobile shield elastomer flexible cable Power connection of various underground mobile coal mining devices with a rated voltage of 0.38/0.66kV
MYP-0.66/1.14 Coal mine used mobile shield rubber sheathed flexible cable Power connection of various underground mobile coal mining devices with a rated voltage of 0.66/1.44KV
MYPE-0.66/1.14 Coal mine used mobile shield elastomer flexible cable Power connection of various underground mobile coal mining devices with a rated voltage of 0.66/1.44KV


Size

Number of cores×nominal conductor cross section(mm2) Nominal thickness(mm) Cable diameter(mm) Number of cores×nominal conductor cross section(mm2) Nominal thickness(mm) Cable diameter(mm)
Insulation Sheath MY-0.38/0.66
MYE-0.38/0.66
Insulation Sheath MY-0.38/0.66
MYE-0.38/0.66
The minimum value The maximum The minimum value The maximum
1×50 1.6 2.4 18.7 20.5 1×185 2.2 3.4 32.7 35.9
1×70 1.6 2.6 20.9 23.0 1×240 2.4 3.5 35.3 38.8
1×95 1.8 2.8 24.2 26.6 1×300 2.6 3.6 40.0 43.3
1×120 1.8 3.0 26.4 29.0 1×400 2.8 3.8 43.4 47.7
1×150 2.0 3.2 30.1 33.0          

 

Number of cores×nominal conductor cross section(mm2) Power line core nominal insulation thickness
(mm)
Sheathed nominal thickness
(mm)
Cable diameter(mm)
Core power lines Ground wire core MY-0.38/0.66
MYE-0.38/0.66
MYP-0.38/0.66
MYPE-0.38/0.66
The minimum value The maximum The minimum value The maximum
3×4 1×4 1.4 3.5 20.9 23.0 22.9 25.2
3×6 1×6 1.4 3.5 22.9 25.1 24.7 27.2
3×10 1×10 1.6 4.0 27.8 30.6 29.7 32.7
3×16 1×10 1.6 4.0 30.3 33.3 32.2 35.4
3×50 1×16 1.8 4.5 36.4 40.1 38.3 41.0
3×35 1×16 1.8 4.5 40.5 44.6 42.4 46.6
3×50 1×16 2.0 5.0 45.5 50.1 47.7 51.0
3×70 1×25 2.0 5.0 51.5 55.1 52.4 57.1

 

Number of cores×nominal conductor cross section(mm2) Power line core nominal insulation thickness
(mm)
Sheathed nominal thickness
(mm)
Cable diameter(mm)
Core power lines Ground wire core MYP-0.66/1.44
The minimum value The maximum
3×10 1×16 1.8 4.5 31.7 34.9
3×16 1×10 1.8 4.5 34.2 37.6
3×25 1×16 2.0 5.0 40.3 44.3
3×35 1×16 2.0 5.0 44.4 48.8
3×50 1×16 2.2 5.5 51.5 54.6
3×70 1×25 2.2 5.5 53.9 59.3
3×95 1×25 2.4 6.0 62.1 68.1


The technical requirements

Power line core insulation resistance:Table 5

Table 5

Nominal power line core section
mm
Minimum insulation resistance at 20 ℃ ≤ (MΩ.km)
4 200
6 180
10 160
16 120
25 120
35 100
50 100
70 80
95 80
- -

1)Tearing strength of the outer sheath rubber is not less than 7.5N/mm
2)Other electrical properties of the product are subject to GB3048 specification

Corresponding parameter set not found, please add it in property template of background