PRODUCTS CENTER

>
>
>
1.9/3.3kV and below coal mine used mobile flame-retardant coal cutter flexible cable
Page view
产品名称

1.9/3.3kV and below coal mine used mobile flame-retardant coal cutter flexible cable

没有此类产品
Contact Us
PRODUCT DESCRIPTION

Use
This product is mining used rubber sheathed flexible cable series and suitable for power connection of coal cutters with a rated voltage Uo/U of 1.9/3.3/kV and below and similar equipment.

Working conditions
The long-term allowable working temperature of the wire core is 65℃, the minimum bending radius of the cable is 6 times of the cable diameter. The yellow sheathed cable shall not be exposed to sunlight for a long time.


Type、Name、Use

Type Name Use
MC-0.38/0.66 Coal cutter rubber sheathed flexible cable Power connection of coal cutters with a rated voltage of .038/0.66kV and similar equipment
MCP-0.38/0.66 Coal cutter shield rubber sheathed flexible cable Power connection of coal cutters with a rated voltage of .038/0.66kV and similar equipment
MCP-0.66/1.14 Coal cutter shield rubber sheathed flexible cable Power connection of coal cutters with a rated voltage of 0.66/1.44KV and similar equipment
MCP-1.9/3.3 Coal cutter shield rubber sheathed flexible cable Power connection of coal cutters with a rated voltage of 1.9/3.3KV and similar equipment


Size

Number of cores×nominal conductor cross section(mm2) Power line core nominal insulation thickness
(mm)
Sheathed nominal thickness 
(mm)
Cable diameter(mm)
Core power lines Ground wire core The line of control core MC-0.38/0.66 MCP-0.38/0.66
The minimum value The maximum The minimum value The maximum
3×16 1×4 3×2.5 1.6 4.5 31.3 34.4 33.2 36.5
3×25 1×6 4×2.5 1.8 5.5 38.4 41.0 40.3 44.3
3×35 1×6 4×4 1.8 5.5 43.9 48.3 45.8 50.4
3×50 1×10 7×4 2.0 5.5 47.7 51.0 51.5 55.0

 

Number of cores×nominal conductor cross section(mm2) Nominal thickness(mm) Cable diameter (mm)
Core power lines Ground wire core The line of control core Power line core insulation
(mm)
Sheath (type A) Sheath (type B) MCP-1.9/3.3
Type A minimum The maximum value of B Type A minimum The maximum value of B
3×35 1×16 - 2.0 6.0 7.0 47.8 51.0 53.2 58.7
3×50 1×10 3×16/3 2.2 7.0 7.5 53.5 58.9 59.0 63.0
3×75 1×16 3×25/3 2.2 7.0 7.5 58.9 63.0 63.8 70.2
3×95 1×25 3×35/3 2.4 7.0 7.5 64.9 71.4 68.7 75.6

 

Number of cores×nominal conductor cross section(mm2) Nominal thickness(mm) Cable diameter(mm)
Core power lines Ground wire core The line of control core Power line core insulation
(mm)
Sheath (type A) Sheath (type B) MCP-1.9/3.3
Type A minimum The maximum value of A Type B minimum The maximum value of B
3×35 1×16 3×16/3 2.8 6.0 7.0 52.1 56.8 60.0 63.0
3×50 1×10 3×25/3 2.8 7.0 7.5 56.4 62.0 63.8 70.2
3×75 1×16 3×35/3 3.0 7.0 7.5 62.7 69.0 69.0 75.9
3×95 1×25 3×50/3 3.0 7.0 7.5 67.8 74.6 73.1 78.0

The technical requirements

The conductor of the cable insulation resistance in accordance with table 5. Table 5

Wire core type Nominal cross section
(mm2)
Insulation resistance of 20 ℃(MΩ.km)
Rated voltage up to and including 0.66/1.14 kV Rated voltages up to and including 1.9/3.3 kV
Core power lines 16 ≥120
25 ≥120
35 ≥100 ≥380
50 ≥100 ≥350
70 ≥80 ≥320
95 ≥80 ≥280
The line of control core   ≥100 ≥100

 

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待