• 0.66/1.14kV and below mobile flame-retardant soft cables for coal mines
0.66/1.14kV and below mobile flame-retardant soft cables for coal mines
+

0.66/1.14kV and below mobile flame-retardant soft cables for coal mines

Product classification

Keywords

  • Product Description
  • Purpose
    This product is a series of rubber-sheathed flexible cables for mining use. It is suitable for connecting power supply lines for mobile coal mining machines and other equipment with a rated voltage of 0.66/1.14KV and below.

    Usage Conditions
    The long-term allowable working temperature of the cable conductor is 65℃. The minimum bending radius of the cable is 6 times the diameter of the cable. Yellow sheathed cables should not be exposed to sunlight for long periods.

    Model, Name, Purpose

    Model Name Purpose
    MY-0.38/0.66 Mobile rubber-sheathed flexible cable for coal mines Power connection for various underground mobile coal mining equipment with a rated voltage of 0.38/0.66KV
    MYE-0.38/0.66 Mobile elastomer flexible cable for coal mines Power connection for various underground mobile coal mining equipment with a rated voltage of 0.38/0.66KV
    MYP-0.38/0.66 Mobile shielded rubber-sheathed flexible cable for coal mines Power connection for various underground mobile coal mining equipment with a rated voltage of 0.38/0.66KV
    MYPE-0.38/0.66 Mobile shielded elastomer flexible cable for coal mines Power connection for various underground mobile coal mining equipment with a rated voltage of 0.38/0.66KV
    MYP-0.66/1.14 Mobile shielded rubber-sheathed flexible cable for coal mines Power connection for various underground mobile coal mining equipment with a rated voltage of 0.66/1.44KV
    MYPE-0.66/1.14 Mobile shielded elastomer flexible cable for coal mines Power connection for various underground mobile coal mining equipment with a rated voltage of 0.66/1.44KV

     

    Specifications and Dimensions

    Number of Cores × Nominal Conductor
    Cross-section (mm2)
    Nominal Thickness (mm) Cable Outer Diameter (mm) Number of Cores × Nominal Conductor
    Cross-section (mm2)
    Nominal Thickness (mm) Cable Outer Diameter (mm)
    Insulation Sheath MY-0.38/0.66
    MYE-0.38/0.66
    Insulation Sheath MY-0.38/0.66
    MYE-0.38/0.66
    Minimum Value Maximum Value Minimum Value Maximum Value
    1×50 1.6 2.4 18.7 20.5 1×185 2.2 3.4 32.7 35.9
    1×70 1.6 2.6 20.9 23.0 1×240 2.4 3.5 35.3 38.8
    1×95 1.8 2.8 24.2 26.6 1×300 2.6 3.6 40.0 43.3
    1×120 1.8 3.0 26.4 29.0 1×400 2.8 3.8 43.4 47.7
    1×150 2.0 3.2 30.1 33.0          

     

    Number of Cores × Nominal Cross-section (mm2) Power Line Core Insulation
    Nominal Thickness
    (mm)
    Sheath Nominal Thickness
    (mm)
    Cable Outer Diameter (mm)
    Power Line Core Ground Wire Core MY-0.38/0.66
    MYE-0.38/0.66
    MYP-0.38/0.66
    MYPE-0.38/0.66
    Minimum Value Maximum Value Minimum Value Maximum Value
    3×4 1×4 1.4 3.5 20.9 23.0 22.9 25.2
    3×6 1×6 1.4 3.5 22.9 25.1 24.7 27.2
    3×10 1×10 1.6 4.0 27.8 30.6 29.7 32.7
    3×16 1×10 1.6 4.0 30.3 33.3 32.2 35.4
    3×50 1×16 1.8 4.5 36.4 40.1 38.3 41.0
    3×35 1×16 1.8 4.5 40.5 44.6 42.4 46.6
    3×50 1×16 2.0 5.0 45.5 50.1 47.7 51.0
    3×70 1×25 2.0 5.0 51.5 55.1 52.4 57.1

     

    Number of Cores × Nominal Cross-section (mm2) Power Line Core Insulation Standard Thickness
    3×25
    (mm)
    Sheath Nominal Thickness
    (mm)
    Cable Outer Diameter (mm)
    Power Line Core Ground Wire Core MYP-0.66/1.44
    Minimum Value Maximum Value
    3×10 1×16 1.8 4.5 31.7 34.9
    3×16 1×10 1.8 4.5 34.2 37.6
    3×95 1×16 2.0 5.0 40.3 44.3
    3×35 1×16 2.0 5.0 44.4 48.8
    3×50 1×16 2.2 5.5 51.5 54.6
    3×70 1×25 2.2 5.5 53.9 59.3
    Technical Requirements 1×25 2.4 6.0 62.1 68.1


    Power line core insulation resistance: see Table 5

    Table 5

    Power Line Core Nominal Cross-section

    mm
    Insulation resistance at 20℃ ≤ (MΩ.km) minimum value
    1. The outer sheath rubber has a tear strength of not less than 7.5N/mm.
    4 200
    6 180
    10 160
    16 120
    25 120
    35 100
    50 100
    70 80
    95 80
    - -

    2. Other electrical performance of the product complies with GB3048 specifications.
    2、产品的其它电气性能按GB3048规格。

0.66/1.14kV and below mobile flame-retardant soft cables for coal mines

Product classification

Keywords

Online inquiry

If you have any questions about our products and services, please contact us!

Online Message

If you have any questions about our products and services, please contact us!

Submit