1.9/3.3kV and below flame-retardant soft cables for mobile coal mining machines
Product classification
Keywords
- Product Description
-
Purpose
This product is a series of rubber-sheathed flexible cables for mining. It is suitable for power connections of coal mining machines and similar equipment with a rated voltage Uo/U of 1.9/3.3kV and below.
Usage Conditions
The long-term allowable working temperature of the conductor is 65℃, and the minimum bending radius of the cable is 6 times the diameter of the cable. Yellow sheathed cables should not be exposed to sunlight for long periods.
Model, Name, PurposeModel Name Purpose MC-0.38/0.66 Coal Mining Machine Rubber-Sheathed Flexible Cable Power connection for coal mining and similar equipment with a rated voltage of 0.38/0.66KV MCP-0.38/0.66 Coal Mining Machine Shielded Rubber-Sheathed Flexible Cable Power connection for coal mining and similar equipment with a rated voltage of 0.38/0.66KV MCP-0.66/1.14 Coal Mining Machine Shielded Rubber-Sheathed Flexible Cable Power connection for coal mining and similar equipment with a rated voltage of 0.66/1.44KV MCP-1.9/3.3 Coal Mining Machine Shielded Rubber-Sheathed Flexible Cable Power connection for coal mining and similar equipment with a rated voltage of 1.9/3.3KV
SpecificationsNumber of Cores × Nominal Cross-Section (mm2) Power Conductor Insulation
Nominal Thickness
(mm)Sheath Nominal Thickness
(mm)Cable Outer Diameter (mm) Power Conductor Ground Conductor Control Conductor MC-0.38/0.66 MCP-0.38/0.66 Minimum Value Maximum Value Minimum Value Maximum Value 3×16 1×4 3×2.5 1.6 4.5 31.3 34.4 33.2 36.5 3×25 1×6 4×2.5 1.8 5.5 38.4 41.0 40.3 44.3 3×35 1×6 4×4 1.8 5.5 43.9 48.3 45.8 50.4 3×50 1×10 7×4 2.0 5.5 47.7 51.0 51.5 55.0 Number of Cores × Nominal Cross-Section (mm2) Nominal Thickness (mm) Cable Outer Diameter (mm) Power Conductor Ground Conductor Control Conductor Power Conductor Insulation
(mm)Sheath (Type A) Sheath (Type B) MCP-1.9/3.3 Type A
Minimum ValueType B
Maximum ValueType A
Minimum ValueType B
Maximum Value3×35 1×16 - 2.0 6.0 7.0 47.8 51.0 53.2 58.7 3×50 1×10 3×16/3 2.2 7.0 7.5 53.5 58.9 59.0 63.0 3×75 1×16 3×25/3 2.2 7.0 7.5 58.9 63.0 63.8 70.2 3×95 1×25 3×35/3 2.4 7.0 7.5 64.9 71.4 68.7 75.6 Number of Cores × Nominal Cross-Section (mm2) Nominal Thickness (mm) Cable Outer Diameter (mm) Power Conductor Ground Conductor Control Conductor Power Conductor Insulation
(mm)Sheath
(Type A)Sheath
(Type B)MCP-1.9/3.3 Type A
Minimum ValueType A
Maximum ValueType B
Minimum ValueType B
Maximum Value3×35 1×16 3×16/3 2.8 6.0 7.0 52.1 56.8 60.0 63.0 3×50 1×10 3×25/3 2.8 7.0 7.5 56.4 62.0 63.8 70.2 3×75 1×16 3×35/3 3.0 7.0 7.5 62.7 69.0 69.0 75.9 3×95 1×25 3×50/3 3.0 7.0 7.5 67.8 74.6 73.1 78.0 Technical Requirements
The insulation resistance of the cable conductor complies with the provisions of Table 5. Table 5
Conductor Type Nominal Cross-Section
(mm2)Insulation Resistance at 20℃ (MΩ.km) Rated Voltage 0.66/1.14kV
and belowRated Voltage 1.9/3.3kV Power Conductor 16 >=120 - 25 >=120 - 35 >=100 >=380 50 >=100 >=350 70 >=80 >=320 95 >=80 >=280 Control Conductor >=100 >=100