• 1.9/3.3kV and below flame-retardant soft cables for mobile coal mining machines
1.9/3.3kV and below flame-retardant soft cables for mobile coal mining machines
+

1.9/3.3kV and below flame-retardant soft cables for mobile coal mining machines

Product classification

Keywords

  • Product Description
  • Purpose
    This product is a series of rubber-sheathed flexible cables for mining. It is suitable for power connections of coal mining machines and similar equipment with a rated voltage Uo/U of 1.9/3.3kV and below.

    Usage Conditions
    The long-term allowable working temperature of the conductor is 65℃, and the minimum bending radius of the cable is 6 times the diameter of the cable. Yellow sheathed cables should not be exposed to sunlight for long periods.


    Model, Name, Purpose

    Model Name Purpose
    MC-0.38/0.66 Coal Mining Machine Rubber-Sheathed Flexible Cable Power connection for coal mining and similar equipment with a rated voltage of 0.38/0.66KV
    MCP-0.38/0.66 Coal Mining Machine Shielded Rubber-Sheathed Flexible Cable Power connection for coal mining and similar equipment with a rated voltage of 0.38/0.66KV
    MCP-0.66/1.14 Coal Mining Machine Shielded Rubber-Sheathed Flexible Cable Power connection for coal mining and similar equipment with a rated voltage of 0.66/1.44KV
    MCP-1.9/3.3 Coal Mining Machine Shielded Rubber-Sheathed Flexible Cable Power connection for coal mining and similar equipment with a rated voltage of 1.9/3.3KV


    Specifications

    Number of Cores × Nominal Cross-Section (mm2) Power Conductor Insulation
    Nominal Thickness
    (mm)
    Sheath Nominal Thickness
    (mm)
    Cable Outer Diameter (mm)
    Power Conductor Ground Conductor Control Conductor MC-0.38/0.66 MCP-0.38/0.66
    Minimum Value Maximum Value Minimum Value Maximum Value
    3×16 1×4 3×2.5 1.6 4.5 31.3 34.4 33.2 36.5
    3×25 1×6 4×2.5 1.8 5.5 38.4 41.0 40.3 44.3
    3×35 1×6 4×4 1.8 5.5 43.9 48.3 45.8 50.4
    3×50 1×10 7×4 2.0 5.5 47.7 51.0 51.5 55.0

     

    Number of Cores × Nominal Cross-Section (mm2) Nominal Thickness (mm) Cable Outer Diameter (mm)
    Power Conductor Ground Conductor Control Conductor Power Conductor Insulation
    (mm)
    Sheath (Type A) Sheath (Type B) MCP-1.9/3.3
    Type A
    Minimum Value
    Type B
    Maximum Value
    Type A
    Minimum Value
    Type B
    Maximum Value
    3×35 1×16 - 2.0 6.0 7.0 47.8 51.0 53.2 58.7
    3×50 1×10 3×16/3 2.2 7.0 7.5 53.5 58.9 59.0 63.0
    3×75 1×16 3×25/3 2.2 7.0 7.5 58.9 63.0 63.8 70.2
    3×95 1×25 3×35/3 2.4 7.0 7.5 64.9 71.4 68.7 75.6

     

    Number of Cores × Nominal Cross-Section (mm2) Nominal Thickness (mm) Cable Outer Diameter (mm)
    Power Conductor Ground Conductor Control Conductor Power Conductor Insulation
    (mm)
    Sheath
    (Type A)
    Sheath
    (Type B)
    MCP-1.9/3.3
    Type A
    Minimum Value
    Type A
    Maximum Value
    Type B
    Minimum Value
    Type B
    Maximum Value
    3×35 1×16 3×16/3 2.8 6.0 7.0 52.1 56.8 60.0 63.0
    3×50 1×10 3×25/3 2.8 7.0 7.5 56.4 62.0 63.8 70.2
    3×75 1×16 3×35/3 3.0 7.0 7.5 62.7 69.0 69.0 75.9
    3×95 1×25 3×50/3 3.0 7.0 7.5 67.8 74.6 73.1 78.0

    Technical Requirements

    The insulation resistance of the cable conductor complies with the provisions of Table 5. Table 5

    Conductor Type Nominal Cross-Section
    (mm2)
    Insulation Resistance at 20℃ (MΩ.km)
    Rated Voltage 0.66/1.14kV
    and below
    Rated Voltage 1.9/3.3kV
    Power Conductor 16 >=120
    25 >=120
    35 >=100 >=380
    50 >=100 >=350
    70 >=80 >=320
    95 >=80 >=280
    Control Conductor   >=100 >=100

     

1.9/3.3kV and below flame-retardant soft cables for mobile coal mining machines

Product classification

Keywords

Online inquiry

If you have any questions about our products and services, please contact us!

Online Message

If you have any questions about our products and services, please contact us!

Submit