    With the rapid development of our national economy, the construction of subways, airports, tunnels, bridges, and large-scale buildings in medium and large cities urgently requires a type of power distribution line that meets environmental protection requirements and adapts to the characteristics of the aforementioned buildings.

    To meet market demand, Shanghai Suogu Cable Group's new product research institute has specially developed and manufactured large cross-section armored prefabricated multi-core branch cables that meet environmental protection requirements, and has already entered mass production. The model specifications include: ordinary type, cross-linked type, flame-retardant type, fire-resistant type, safe and clean type, and oxygen barrier flame-retardant fire-resistant type. The maximum cross-section of the cable can reach: 240mm2/phase; branch cross-sections can be produced according to user requirements.

    Armored Multi-Core Branch Cable Model Demonstration



    Armored Multi-Core Safe and Clean (Environmental Protection) Branch Cable Model Demonstration




    VV PVC Insulated PVC Sheathed 4-Core Power Cable Parameters (0.6/1kv)

    Conductor Nominal
    Cross-Sectional Area
    (mm2)
    Insulation Thickness
    (mm)
    Sheath Thickness
    (mm)
    Approximate Outer Diameter
    (mm)
    Approximate Weight
    (kg/km)
    20℃ Conductor
    Maximum Resistance
    Ω/km
    Rated Current A Voltage Drop
    (mV/m)
    In Air at 40℃ In Air at 30℃
    4×10
    4×16
    1.0
    1.0
    1.8
    1.8
    18.6
    20.8
    682
    1010
    1.83
    1.15
    52
    70
    60
    80
    84
    69
    4×25
    4×35
    1.2
    1.2
    1.8
    1.9
    24.7
    27.1
    1411
    1835
    0.727
    0.524
    88
    110
    101
    126
    56
    50
    4×50
    4×70
    1.4
    1.4
    1.9
    2.2
    28.2
    32
    2435
    3271
    0.387
    0.268
    133
    170
    153
    196
    45
    39
    4×95
    4×120
    1.6
    1.6
    2.3
    2.5
    36.7
    43
    4338
    5383
    0.193
    0.153
    207
    240
    238
    276
    36
    32
    4×150
    4×185
    1.8
    2.0
    2.6
    2.8
    47.7
    52.7
    6712
    8207
    0.124
    0.0991
    277
    316
    319
    364
    30
    28
    4×240
    4×300
    2.2
    2.4
    3.0
    3.2
    59.4
    65.2
    10850
    13647
    0.0754
    0.0601
    374
    432
    430
    497
    25
    23


    VV PVC Insulated PVC Sheathed 4+1 Core Power Cable Parameters (0.6/1kv)

    Conductor Nominal
    Cross-Sectional Area
    (mm2)
    Insulation Thickness
    (mm)
    Sheath Thickness
    (mm)
    Approximate Outer Diameter
    (mm)
    Approximate Weight
    (kg/km)
    20℃ Conductor
    Maximum Resistance
    Ω/km
    Rated Current A Voltage Drop
    (mV/m)
    In Air at 40℃ In Air at 30℃
    4×10+1×6
    4×16+1×10
    1.0
    1.0
    1.8
    1.9
    18
    20.7
    720
    1055
    1.83
    1.15
    52
    70
    60
    80
    84
    69
    4×25+1×16
    4×35+1×16
    1.2
    1.2
    1.9
    1.9
    24.6
    26.8
    1578
    1988
    0.727
    0.524
    88
    110
    101
    126
    56
    50
    4×50+1×25
    4×70+1×35
    1.4
    1.4
    2.1
    2.2
    28.5
    30.6
    2683
    3609
    0.387
    0.268
    133
    170
    153
    196
    45
    39
    4×95+1×50
    4×120+1×70
    1.6
    1.6
    2.4
    2.5
    34.7
    38.1
    4836
    6055
    0.193
    0.153
    207
    240
    238
    276
    36
    32
    4×150+1×70
    4×185+1×95
    1.8
    2.0
    2.7
    2.9
    42.6
    47.4
    7384
    8911
    0.124
    0.0991
    277
    316
    319
    364
    30
    28
    4×240+1×120 2.2 3.1 53.2 11414 0.0754 374 430 25


    YJV Cross-Linked Polyethylene Insulated PVC Sheathed 3+1 Core Power Cable Parameters (0.6/1kv)

    Conductor Nominal
    Cross-Sectional Area
    (mm2)
    Insulation Thickness
    (mm)
    Sheath Thickness
    (mm)
    Approximate Outer Diameter
    (mm)
    Approximate Weight
    (kg/km)
    20℃ Conductor
    Maximum Resistance
    Ω/km
    Rated Current A Voltage Drop
    (mV/m)
    In Air at 40℃ In Air at 30℃
    3×10+1×6
    3×16+1×10
    0.7/0.7
    0.7/0.7
    1.8
    1.8
    16.4
    18.5
    503
    727
    1.83
    1.15
    68
    91
    75
    100
    84
    69
    3×25+1×16
    3×35+1×16
    0.9/0.7
    0.9/0.7
    1.8
    1.8
    22.3
    24.8
    1092
    1476
    0.727
    0.524
    116
    144
    127
    158
    56
    50
    3×50+1×25
    3×70+1×35
    1.0/0.9
    1.1/0.9
    1.8
    1.9
    25.9
    29.9
    1907
    2612
    0.387
    0.268
    174
    224
    192
    246
    45
    39
    3×95+1×50
    3×120+1×70
    1.1/1.0
    1.2/1.1
    2.1
    2.2
    33.7
    37.5
    3489
    4448
    0.193
    0.153
    271
    315
    298
    346
    36
    32
    3×150+1×70
    3×185+1×95
    1.4/1.1
    1.6/1.1
    2.3
    2.5
    41.6
    46.7
    5383
    6711
    0.124
    0.0991
    363
    415
    399
    456
    30
    28
    3×240+1×120
    3×300+1×150
    1.7/1.2
    1.8/1.4
    2.7
    2.9
    51.9
    57
    8561
    11080
    0.0754
    0.0601
    490
    565
    538
    620
    25
    23


    YJV Cross-Linked Polyethylene Insulated PVC Sheathed 4-Core Power Cable Parameters (0.6/1kv)

    Conductor Nominal
    Cross-Sectional Area
    (mm2)
    Insulation Thickness
    (mm)
    Sheath Thickness
    (mm)
    Approximate Outer Diameter
    (mm)
    Approximate Weight
    (kg/km)
    20℃ Conductor
    Maximum Resistance
    Ω/km
    Rated Current A Voltage Drop
    (mV/m)
    In Air at 40℃ In Air at 30℃
    4×10
    4×16
    4×25
    0.7
    0.7
    0.9
    1.8
    1.8
    1.8
    18.6
    20
    20
    610
    879
    1286
    1.83
    1.15
    0.727
    68
    91
    116
    75
    100
    127
    84
    69
    56
    4×35
    4×50
    0.9
    1.0
    1.9
    1.9
    26
    28
    1688
    2341
    0.524
    0.387
    144
    174
    158
    192
    50
    45
    4×70
    4×95
    1.1
    1.1
    2.2
    2.3
    33
    36
    3175
    4171
    0.268
    0.193
    224
    271
    246
    298
    39
    36
    4×120
    4×150
    1.2
    1.4
    2.5
    2.6
    37
    39.5
    5262
    6542
    0.153
    0.124
    315
    363
    346
    399
    32
    30
    4×185
    4×240
    1.6
    1.7
    2.8
    3.0
    45
    54
    7893
    10215
    0.0991
    0.0754
    415
    490
    456
    538
    28
    25
    4×300 1.8 3.2 58 11643 0.0601 565 620 23


    YJV Cross-Linked Polyethylene Insulated PVC Sheathed 4+1 Core Power Cable Parameters (0.6/1kv)

    Conductor Nominal
    Cross-Sectional Area
    (mm2)
    Insulation Thickness
    (mm)
    Sheath Thickness
    (mm)
    Approximate Outer Diameter
    (mm)
    Approximate Weight
    (kg/km)
    20℃ Conductor
    Maximum Resistance
    Ω/km
    Rated Current A Voltage Drop
    (mV/m)
    In Air at 40℃ In Air at 30℃
    4×10+1×6
    4×16+1×10
    0.7
    0.7
    1.8
    1.8
    18
    20.7
    619
    911
    1.83
    1.15
    68
    91
    75
    100
    84
    69
    4×25+1×16
    4×35+1×16
    0.9
    0.9
    1.8
    1.8
    24.6
    26.8
    1359
    1749
    0.727
    0.524
    116
    144
    127
    158
    56
    50
    4×50+1×25
    4×70+1×35
    1.0
    1.1
    1.9
    2.0
    28.5
    30.6
    2387
    3280
    0.387
    0.268
    174
    224
    192
    246
    45
    39
    4×95+1×50
    4×120+1×70
    1.1
    1.2
    2.2
    2.4
    34.7
    38.1
    4407
    5580
    0.193
    0.153
    271
    315
    298
    346
    36
    32
    4×150+1×70
    4×185+1×95
    1.4
    1.6
    2.5
    2.6
    42.6
    47.4
    6803
    8158
    0.124
    0.0991
    363
    415
    399
    456
    30
    28
    4×240+1×120 1.7 2.8 53.2 10850 0.0754 490 538 25


    Steel Tape Armored Multi-Core Power Cable Parameters (0.6/1KV)

    Conductor Nominal
    Cross-Sectional Area
    (mm2)
    Approximate Outer Diameter (mm) Approximate Weight (kg/km)
    VV22 YJV22 VV22 YJV22
    3+1 Core 4 Core 4+1 Core 5 Core 3+1 Core 4 Core 4+1 Core 5 Core 3+1 Core 4 Core 4+1 Core 5 Core 3+1 Core 4 Core 4+1 Core 5 Core
    4
    6
    17.9
    19.5
    18.5
    19.7
    19.2
    20.8
    19.7
    21.3
    16
    17
    17
    17
    17
    18
    17
    19
    538
    657
    565
    685
    605
    765
    644
    790
    425
    527
    445
    550
    485
    637
    507
    638
    10
    16
    22.1
    24.7
    22.8
    25.3
    23.9
    26.9
    24.6
    27.4
    20
    23
    20
    23
    21
    24
    22
    25
    894
    1194
    960
    1273
    1052
    1482
    1110
    1485
    734
    1019
    787
    1076
    882
    1208
    926
    1277
    25
    35
    28.5
    31.7
    30.5
    33.5
    32.4
    35.1
    33.3
    36.6
    26
    28
    27
    29
    28
    30
    28
    33
    1668
    2243
    1998
    2505
    2312
    2756
    2339
    2953
    1434
    1757
    1519
    1957
    1713
    2152
    1817
    2705
    50
    70
    35
    38.5
    35.2
    38.7
    39.7
    44
    41.6
    45.5
    31
    36
    33
    38
    36
    41
    37
    42
    2852
    3657
    3122
    4025
    3680
    4768
    3975
    5125
    2229
    3386
    2759
    3678
    3263
    4376
    3525
    4732
    95
    120
    44.3
    49
    44.7
    49.4
    50.2
    55.1
    52.1
    57.3
    40
    44
    42
    47
    46
    51
    48
    53
    4796
    5912
    5291
    6464
    6267
    7689
    6798
    8217
    4397
    5468
    4832
    5906
    5695
    7129
    6256
    7571
    150
    185
    53.5
    58.9
    53.7
    58.9
    59.9
    66.5
    63.1
    69.9
    49
    52
    52
    56
    55
    61
    58
    65
    7025
    8598
    7866
    9542
    9216
    11293
    10030
    12275
    6464
    8004
    7186
    8807
    8282
    10287
    9221
    11319
    240
    300
    60.6
    65.6
    61
    66.2
    74
    81.9
    77.1
    86.5
    58
    63
    62
    68
    69
    76
    73
    80
    10631
    12913
    11916
    14501
    14371
    17385
    15077
    19395
    10140
    12445
    11268
    13824
    13163
    16169
    14631
    17948

    Note: The remaining parameters are the same as similar (VV, YJV), same cross-section, same core number power cables.


    Note: The rated current of VV and YJV type cables is based on the following standard laying conditions.
    (1) VV plastic insulation
    a. Maximum working temperature of conductor = 70℃ b. Ambient air temperature 40℃ c. Ground temperature over 25℃ d. Soil thermal resistance 1.0K.m/W e. Burial depth 0.5m
    (2) YJV insulation
    a. Maximum working temperature of conductor = 90℃ b. Ambient air temperature 40℃ c. Ground temperature over 25℃ d. Soil thermal resistance 1.0K.m/W e. Burial depth 0.5m

YDF Prefabricated Armored Multi-Core Branch Cable

Product classification

Keywords

Online inquiry

If you have any questions about our products and services, please contact us!

Online Message

If you have any questions about our products and services, please contact us!

Submit